EMI-EMC Testing

EMI/EMC TEST FACILITY

Electromagnetic Compatibility Test Services (EMC-TS) is a wing of Astra Microwave Products Limited has established state of the art EMC test facilities in the year 2014 to provide EMI/EMC testing for the systems and subsystems developed for Defense and Space Applications. This facility is primarily established for pre compliance of our product testing during development stage and final compliance testing. As an independent entity these facilities are being extended to other industries on chargeable basis, to generate revenue.

EMC TEST SERVICES has developed a strong reputation as one of the leading MIL-STD-461 testing labs in the country. This facility has been accredited as per ISO/IEC 17025:2017 standard by  National Accreditation Board for Test and Calibration Laboratory (NABL) which is a constituent body of Quality Council of India (QCI).
Our engineering team takes great pride in thoroughly understanding the  MIL STD 461 and  MIL STD 704 test requirements and being able to apply that knowledge to benefit customers who are experiencing compliance challenges with their devices. The team has capability to analyze EMI problems and implement appropriate control techniques to achieve EMC.

EMC TS-SALIENT FEATURES

The scope of testing is according to the following standards

MIL-STD-461

Requirements for the control of electromagnetic interference (EMI) characteristics of subsystems and equipment covering both Emission and Susceptibility requirements

MIL-STD-704

Aircraft Electrical Power Characteristics

Scope of test facilities under NABL Accreditation:

Test Title Specification/Standard against which tests are performed Range of Testing
Conducted Emissions, Power leads
CE01, MIL-STD-461C
CE03, MIL-STD-461C
CE101, MIL-STD-461 D/E/F/G
30 Hz to 15 kHz,
15 kHz to 50 MHz,
30 Hz to 10 kHz
Conducted Emission, Power leads
CE102, MIL-STD-461 D/E/F/G
10 kHz to 10 MHz
Conducted Emissions, Antenna Terminal
CE06, MIL-STD-461C CE106, MIL-STD-461 D/E/F/G
10 kHz to 40 GHz
Radiated Emissions, Magnetic Field
RE01, MIL-STD-461C
RE101, MIL-STD-461 D/E/F/
30 Hz to 50 kHz
30 Hz to 100 kHz
Radiated Emissions, Electric Field
RE02, MIL-STD-461C
RE102, MIL-STD-461 D/E/F/G
10 kHz to 10 GHz
10 kHz to 18 GHz
Radiated Emission, Antenna Spurious and Harmonic Outputs
RE03, MIL-STD-461C RE103, MIL-STD-461 D/E/F/G
10 kHz to 40 GHz
Conducted Susceptibility, Power Leads
CS01, MIL-STD-461C
CS101, MIL-STD-461 D/E/F/G
30 Hz to 50 kHz,
30 Hz to 150 kHz
Conducted Susceptibility, Intermodulation
CS03, MIL-STD-461C CS103, MIL-STD-461 D/E/F/G
15 kHz to 10 GHz
Conducted Susceptibility, Rejection of Undesired Signal
CS04, MIL-STD-461C CS104, MIL-STD-461 D/E/F/
30 Hz to 20 GHz
Conducted Susceptibility, Antenna Port, Cross-Modulation
CS05, MIL-STD-461C CS105, MIL-STD-461 D/E/F/G
30 Hz to 20 GHz
Conducted Susceptibility, Transients Power Leads
CS06, MIL-STD-461C CS106, MIL-STD-461
400V Peak, 5 µs Pulse Width
Conducted Susceptibility, Structure Current
CS09, MIL-STD-461C CS109, MIL-STD-461 D/E/F/G
60 Hz to 100 kHz
Conducted Susceptibility, Bulk cable injection
CS114, MIL-STD-461 D/E/F/G
10 kHz to 200 MHz
Conducted Susceptibility, Impulse Excitation
CS115, MIL-STD-461 D/E/F/G
5 Amperes
Conducted Susceptibility, Damped Sinusoidal Transients
CS116, MIL-STD-461 D/E/F/G
10 kHz to 100 MHz, 10 Amperes
Conducted Susceptibility, Lightning induced transients
CS117, MIL- STD-461G
Internal Equipment Levels, Waveform 1 to Waveform 6
Personnel borne electrostatic discharge
CS118, MIL- STD-461G
±8 KV Contact Discharge ± 15 KV Air Discharge
Radiated Susceptibility, Magnetic Field
RS01, MIL-STD-461C RS101, MIL-STD-461 D/E/F/G
30 Hz to 50 kHz 30 Hz to 100 kHz
Radiated Susceptibility, Electric Field
RS03, MIL-STD-461C RS103, MIL-STD-461 D/E/F/G
14 kHz to 40GHz, 60 V/m
Electrostatic Discharge Susceptibility
IEC 61000-4-2, IEC 801-2
+/- 30 kV
Aircraft Electrical Power characteristic tests
LDC 102, LDC 103, LDC 105, LDC 201 LDC 301, LDC 302, LDC 401, LDC 501 LDC 601, LDC 602 as per MIL-STD-704 D/E/F
28 Volts DC systems / Max. current: 8.2 A
Shipboard DC Magnetic Field Test
As per Mil-Std-1399 Section 070 – Part
> 1600 A/m
Scroll To Top